Gibbs reactor

Let species react freely into a minimum of Gibbs energy.

Inputs

  • Fluid package: Fluid package containing the reacting components. Must include all possible reactants and products.
  • Heat Ingress: Optional heat duty supplied the reactor.
  • Temperature: Optional outlet temperature specification.
  • Pressure Drop: Pressure loss through the reactor (default zero).
  • inertComponents: Components to exclude from the reaction calculation. For these components, the number of moles in equals the number of moles out.
  • Heat from Source / Heat to Sink: If selected, the heat transferred to/from the reactor is specified by the connected heat flow.
  • Work Calculation: Optional work calculation model (None/No work output (consistent)/Ideal cycle/Non-ideal cycle).
  • COP / Exergy Efficiency: Required for Non-ideal cycle and No work output (consistent).

Outputs

  • Outlet stream at chemical equilibrium.

Details

The Gibbs reactor can act as either a heat-source or a heat-sink, depending on whether the reaction is exo- or endothermic. See the pages on the Heater and Cooler units for more details on using the Heat from Source and Heat to Sink options.